Insulation Piercing Connector for Street Lighting
MODELSMAIN LINE
(MM2)SERVICE LINE
(MM2)BOLT NO.TORQUEREMARKS
PCT13C 95/106-951.5-10110NMISO to ISO
PCT13CB 95/10(B)6-951.5-10110NMISO to Bare
PCT13C 120/106-1201.5-10110NMISO to ISO
PCT13CB 120/10(B)6-1201.5-10110NMISO to Bare
Piercing Connector for Low Voltage Aerial Bundled Cables
MODELSMAIN LINE
(MM2)SERVICE LINE
(MM2)BOLT NO.TORQUE
(NM)REMARKS
PCT13C 70/3516-704-35115NMISO to ISO
PCT13CB 70/3516-70(B)4-35115NMISO to Bare
PCT13C 95/5016-954-50117NMISO to ISO
PCT13CB 95/5016-95(B)4-50117NMISO to Bare
PCT13C 120/2525-1206-25117NMISO to ISO
PCT13C 150/5050-1504-50117NMISO to ISO
PCT13C 185/3550-1856-35117NMISO to ISO
MODELSMAIN LINE
(MM2)SERVICE LINE
(MM2)BOLT NO.TORQUE
(NM)REMARKS
PCT13C 95/9516-9516-95117-23NMISO to ISO
PCT13CB 95/9516-95(B)16-95123NMISO to Bare
PCT13C 150/15016-15016-150123NMISO to ISO
PCT13CB 150/15016-150(B)16-150123NMISO to Bare
MODELSJBC-0JBC-1JBC-2PCT23C 240-240
Main Line(mm2)25-7035-7035-15050-240
Service Line (mm2)6-356-3535-15050-240
Bolt No.1112
Torque (Nm)10NM13NM17NM23NM
RemarksISO to ISOISO to ISOISO to ISOISO to ISO
MODELSEQUAL TO CODEMAIN LINE
(MM2)SERVICE LINE
(MM2)BOLT NO.
CRT041FJTTD041FJ6-351.5-101
CRT051FJTTD051FJ16-951.5-101
CRT101FJTTD101FJ6-502.5-352
CRT151FJTTD151FJ25-952.5-353
CRT201FJTTD201FJ35-9525-954
CRT251FJTTD251FJ50-15025-955
CRT271FJTTD271FJ35-12035-1206
CRT281FJTTD281FJ50-1852.5-357
CRT401FJTTD401FJ50-18550-1502
CRT431FJTTD431FJ70-24016-952
CRT441FJTTD441FJ95-24050-1502
CRT451FJTTD451FJ95-24095-2402
CRT551FJTTD551FJ120-40095-2402
MODELSPCT13 150/150PCT13B 150/150
Main Line(mm2)6-1506-150
Service Line (mm2)6-150(B)6-150
Bolt No.11
Torque (Nm)17NM17NM
RemarksISO to ISOISO to Bare
MODELSIPC 150-35CPL-1PCT23C 95/70
Main Line(mm2)35-15016-9525-95
Service Line (mm2)6-3516-256-70
Bolt No.112
Torque (Nm)17NM17NM17NM
RemarksISO to ISOISO to ISOISO to ISO
10 KV Piercing Tap Connectors
MODELSCRSF10-95/25CRSF10-120/35CRSF10-185/95CRSF10-240/150
Conductor range(mm2)25-9535-12095-185150-240
10 KV Underground IPC Connector
MODELSCRSF10-95/25CRSF10-120/35CRSF10-185/95CRSF10-240/150
Conductor range(mm2)25-9535-12095-185150-240
Insulated Fasten Clamp
MODELSPT 35/25PT 150/35PT 150/35 (B)PT2 150/35PT2 150/35 (B)
Main Line(mm2)2.5-35(16)35-150(16)35-150(16)35-150(16)35-150
Service Line (mm2)10-254-504-502x4-502x4-50
Bolt No.11122
Torque (Nm)9-13NM13-17NM13-17NM13-17NM13-17NM
RemarksISO to ISOISO to ISOISO to ISOISO to ISOISO to ISO
JBDC is to lead the branch from the bare main line while JBDD is to lead the branch from the insulated mainline,tighten the bolt with an idea torque which ensure the best quality of connection.
Material: High strength aIuminium alloy anti-UV plastic
MODELSJBDC-1JBDC-2JBDC-3JBDD-1JBDD-2JBDD-3
Main Line(mm2)6-3550-15050-1506-3550-15050-150
Service Line (mm2)6-356-3535-956-356-3535-95
RemarksBare Main to ISO BranchISO Main to Bare Branch
Multi-Tap Insulation pierciing connector
Adaptor is used to turn multiple conductors of low voltage.Whole adaptor is inserted into the IPC with piercing teeth who penetrate through the insulation.This joint is 100% waterproof.The adaptor can be installed with any IPC who allows you to transfer the required voltage,and has the ability yo carry the required number of conductors.
Standard: IEC 61284, EN 50483, IRAM2435, NFC33 020.
Material: Body in Aluminum alloy with tinned surface coating.Plastic Cover
MODELS:ADAPTOR 2ADAPTOR 4
Main Line(mm2):IPCIPC
Service Line (mm2):RE/RM 2x1.5-35RE/RM 4x1.5-35
Bolt No.:48
Torque (Nm):9NM9NM
Remarks:ISO to ISOISO to ISO
Undergrounding ring type tap off connector
4 core or 3 1/2 core ring type tap off connector with IP2X protection and piercing retardant system.
On the connector ring is pressembled on the main conductor the plastic housing offer full protection against touching live contact teeth(finger test),test to EN 60529.During pressembly on the main conductor the contact protection system detects early contact teeth via the predetermined breaking point to ensure a large operational safety during tap off conductor assembly.
Material
High strength aluminum alloy (AIMgSi),corrosion resistant,Contacts in brass (Cu Zn),electro tinned,insulation parts are glassfiber reinforced PA,screw are steel,grade 8.8.
TYPEROUND CONDUCTORSECTOR CONDUCTORREFERENCE
TORQUE
MainTapMainTap
UTC-1RM/RE 70-95RM/RE 6-70SM/SE 70-95SM/SE 6-5015Nm
UTC-2RM/RE 95-150RM/RE 6-70SM/SE 95-150SM/SE 6-5015Nm
UTC-3RM/RE 95-150RM/RE 6-150SM/SE 95-150SM/SE 6-15015Nm
UTC-4RM/RE 185-240RM/RE 6-70SM/SE 185-240SM/SE 6-5020Nm
Insulation Piercing Connector
The waterproof insulation piercing connectors are suitable for majority types of LV ABC conductors as well as connections to service and lighting cable cores.When tightening the bolts, the teeth of the contact plates penetrate the insulation and establish a perfect contact. The bolts are tightened until the heads shear off. Tightening torque guaranteed (fuse nut). Stripping of insulation is avoided.
Service condition: 400/600V, 50/60Hz, -10℃ to 55℃
Standard: IEC 61284, EN 50483, IRAM2435, NFC33 020.
Material:
Body: Thermoplastic polyamide 66 with fiberglass
Connecting bridge: Copper tinned , Brass tinned, Al
Sealing parts: Flexible PVC
End cap: Flexible PVC
Grease: Silica gel
Bolt: Hot dip galvanized steel, 8.8 grade
Washer , Nut: Hot dip galvanized steel
Fuse nut: Zinc alloy
Features:
• Tested for watertightness at a voltage of 6 kV for 30 min in a waterbath
• Potential free tightening bolts allow safe installations on life lines
• Bimetallic,suitable for aluminium and copper conductors
• Long neck 13 mm shear head nut ensuring reliable installations
• Components not isolated , end cap attached to body
• Insulation material made of weather and UV resistant glass fibre reinforced polymer
How to install insulation piercing connector
Single screw insulation piercing clamp Installation
1.Adjust the nut of the puncture line clamp to a proper position, and insert the branch line into the branch line cap cover.
2.insert the main line. If the main line has two layers of insulation, a certain length of outer insulation should be stripped at the connection position.
3.Put the main and branch lines in the proper position and keep them parallel. First, tighten the nut by hand to fix the clamp.
4.Tighten the nuts evenly with a sleeve wrench of the corresponding size until the top breaks off and the installation is complete.
Single screw installation piercing connector Installation diagram
Twin screw insulation piercing connector installation
1.First unscrew the wire clamp and insert the main wire into the main wire groove. Do not twist the main wire with the knife ruler. Note whether the wire diameter range corresponds to this wire clamp.
2.Put the branch line into the branch line slot. Note the same as above.
3.Tighten with a socket wrench. Disable open-end wrenches.
4.Note that the two nuts should be screwed down synchronously in sequence.
5.When tightened to a certain strength, the constant torque nut is broken and the installation is completed.